Basic Info.

Model NO.
cfl-5/0.8 tank
Structure
General Cylinder
Power
Hydraulic
Standard
Standard, Nonstandard
Pressure Direction
Single-acting Cylinder
Double-Acting Cylinder Type
Common Cylinder
Special Cylinder Type
Number of Cylinders
Combination Cylinder Type
Pressurized Cylinder
Inner Tank:1400*3680*8mm
5m3
Outer Tank:1900*5115*8mm
5m3
Specification
TPED, EN, ISO9809
Trademark
DSW
HS Code
731100
Production Capacity
60days Per Tank

Product Description

Material: Steel
Use: Industrial Gas
Pressure: High
Brand Name: DSW
LO2,LN2,LAR Cryogenic Tank (Vacuum Powder Heat Insulation) Specifications
.LO2 Cryogenic Tank, LN2 Cryogenic Tank, LAR Cryogenic Tank, 5M3 cryogenic tank, 10M3 cryogenic tank, 15M3 cryogenic tank, 20M3 cryogenic tank, 30M3 cryogenic tank, 5M3 VERTICAL CRYOGENIC LIQUID TANK, 1.6MPa cryogenic tank, CRYOGENIC LIQUID TANK, cryogenic Horizontal tank, Vacuum cryogenic tank, china produce cryogenic tank, liquid cryogenic tank, 20m3 Low Temperature Storage Tank Cryogenic Tank, Liquefied Natural Gas LNG/, 5m3-200m3 Cryogenic tank, LNG Natural Gas Cryogenic Storage Tank
CO2 gas cylinder
1. Norminal external diameter: 129mm
2. Norminal water capacity: 5-10Liter
.
LCO2 Cryogenic Tank (Vacuum Powder Heat Insulation) main specification                
Design pressure Inner tank 2.3 Working Pressure Inner tank 2.16 Temperature ºC Inner tank -40
MPa Outer tank -0.1 MPa Outer tank 3Pa Outer tank 50
Loading Medium Inner tank LCO2 Material Inner tank 16?MnDR Test pressure Mpa Inner tank 2.65
Interlayer Brilliant Expansion Perlite Outer tank Q235-B Leak test Interlayer helium test
                 
                 
LCO2 Cryogenic Tank (Vacuum Powder Heat Insulation)        
Type Model Effective Volume Working Pressure Inner tank size (mm)  Weight kg Size mm
M3 MPa   Diameter×Length×Thickness Inner tank weight Total weight Diameter×Length×Thickness
Vertical type DSWV-5/2.16 5 2.16 Φ1400×3680×12 1000 4490 Φ1900×4980×8
DSWV-10/2.16 10 2.16 Φ1700×4960×14 1550 5100 Φ1900×4980×8
DSWV-15/2.16 15 2.16 Φ1900×5920×14 1920 7510 Φ2200×6250×8
DSWV-20/2.16 20 2.16 Φ2000×7075×6 3040 8550 Φ2200×6250×8
DSWV-30/2.16 30 2.16 Φ2400×7460×18 2650 9450 Φ2400×7150×8
DSWV-50/2.16 50 2.16 Φ2600×10395×20 4380 11250 Φ2400×7150×8
DSWV-100/2.16 100 2.16 Φ3000×154525×24 3350 11350 Φ2600×7830×8

About us:
Our company is one of main factory in China Chemical Equipment Group, and as well as the biggest pressure vessel manufacturer in Zhejiang. Sep. Established in 1972 years, We're engaged in design and manufacture pressure vessel for more than 40 years, and have the Design License of Special Equipment (Pressure vessels of type , , ) (RSPZJHG0401-2), It has the following licenses issued by the State Administration of Quality Supervision, Inspection and Quarantine: A1, A2, B3, C2 and C3 pressure vessel manufacturing licenses; the design license for A1, A2, C2 and C3 pressure vessels; and the design license of GC1(3), GC2 and GC3 pressure piping
We have passed ISO9001:2008 International Quality Supervision System Certification.  We own 170000 square meter building size The total assets is 180 million, has 500 workers and staff members, including 55 technician (6 super- engineer, 19 engineer, 10 primary technician, 1 super-technician, 4 technician, 15 Nondestructive Tester (RT, UT). There're 8 departments, such as technology, production, sales, quality, purchase, finance, secretary and standard, 1general management office, 1 international export office (Ningbo DSW), 5 workshops and 1 Installation Company. Set up the Welding Test station with Ningbo Bureau of Quality and Technical Supervision. Quality Guarantee System charged by quality engineer, design engineer, welding.

Lco2 5 M3 Cryogenic Tank
Lco2 5 M3 Cryogenic Tank
Lco2 5 M3 Cryogenic Tank


Inspection guarantee:

The relevant welding seams will be subject to 100% RT non-destructive testing and penetrant testing (PT) according to the technological requirements of storage tank production. High-purity nitrogen (up to 99.999%) will be used to conduct the strength testing. Finally, advanced helium mass spectrometer leak detectors (with precision up to 2×10-9Pa.L/s) will be used to conduct Helium mass spectrometer leak detection. The inner containers of the storage tanks will be passivated by overall pickling to meet the cleanliness requirements for dangerous goods. Imported ultraviolet black light lamps will be used to make sure that there is no oil stain and other organic impurities in the inner containers. The inner and outer containers, after cleaning, will be assembled at a time interval less than 2.5 hours. After assembling, the inner containers and interlayers will be filled with nitrogen to protect them from dust and organic impurities, so as to ensure the cleanliness. The inner and outer surfaces of the outer containers will be subject to overall sandblasting treatment to meet the requirements of Sa-2.5 standard. When the surfaces of steel plates show the metallic color, a vacuum cleaner will be used to suck off the dust adhered to the surface so as to further ensure the vacuum degree in the interlayer. Special high-quality perlite is used as the insulation material in the interlayer. The perlite will be treated by using our company's special process before being in the interlayer. All the internal cylinders, after manufactured, will be subject to the gas-tight and pressure performance tests. Both the internal and outer cylinders will be subject to rigorous Helium mass spectrum leak detection. After the production is completed, all the pipe openings will be opened to carry out nitrogen purging and replacement, so as to meet the oxygen usage standard. After this, all the pipelines and valves will be sealed and the tanks will be filled with 0.2MPa high-purity nitrogen for protecting the tanks.