Customization: | Available |
---|---|
Material: | Steel |
Usage: |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
LCO2 Cryogenic Tank (Vacuum Powder Heat Insulation) main specification | ||||||||
Design pressure | Inner tank | 2.3 | Working Pressure | Inner tank | 2.16 | Temperature ºC | Inner tank | -40 |
MPa | Outer tank | -0.1 | MPa | Outer tank | 3Pa | Outer tank | 50 | |
Loading Medium | Inner tank | LCO2 | Material | Inner tank | 16?MnDR | Test pressure Mpa | Inner tank | 2.65 |
Interlayer | Brilliant Expansion Perlite | Outer tank | Q235-B | Leak test | Interlayer | helium test | ||
LCO2 Cryogenic Tank (Vacuum Powder Heat Insulation) | ||||||||
Type | Model | Effective Volume | Working Pressure | Inner tank size (mm) | Weight kg | Size mm | ||
M3 | MPa | Diameter×Length×Thickness | Inner tank weight | Total weight | Diameter×Length×Thickness | |||
Vertical type | DSWV-5/2.16 | 5 | 2.16 | Φ1400×3680×12 | 1000 | 4490 | Φ1900×4980×8 | |
DSWV-10/2.16 | 10 | 2.16 | Φ1700×4960×14 | 1550 | 5100 | Φ1900×4980×8 | ||
DSWV-15/2.16 | 15 | 2.16 | Φ1900×5920×14 | 1920 | 7510 | Φ2200×6250×8 | ||
DSWV-20/2.16 | 20 | 2.16 | Φ2000×7075×6 | 3040 | 8550 | Φ2200×6250×8 | ||
DSWV-30/2.16 | 30 | 2.16 | Φ2400×7460×18 | 2650 | 9450 | Φ2400×7150×8 | ||
DSWV-50/2.16 | 50 | 2.16 | Φ2600×10395×20 | 4380 | 11250 | Φ2400×7150×8 | ||
DSWV-100/2.16 | 100 | 2.16 | Φ3000×154525×24 | 3350 | 11350 | Φ2600×7830×8 |